Terrace Water proofing

Advantages Waterproofing Chemicals Services

  • Faster waterproofing and no any breakage.
  • There won’t be any collection of heap of sand or cement around the house buildings.
  • There won’t be any dust at all during the work.
  • There is no need to spray water during and after the work.
  • Do not need to worry about any increase in weight of your building
  • In summer there won’t be no any cracks and joints on your surface as the silicon waterproofing chemicals is a Crack-free material.
  • remove all moss, fungi and algae by using wire brush/water jet. Allow the substrate to dry. Ensure the roof slope of a minimum of 1 in 100 already provided. Substrate must be sound. Hairline cracks up to 5mm width should be undercut for ease of application and filled with flexible crack filler. Any loose cracks must be removed electric cutter. Any hollow present in the substrate must be repaired with UltraTech stucco. Allow the repaired area to cure with clean water/moist cure as usual. Surface should be in SSD Condition for application of UltraTech Super Stucco
  • 1.b To ensure proper adhesion, surface should prime with a single coat of Dr.Fixit, Raincoat dilute with water in the ratio 2:1 and apply
  • 1.c Apply 1st coat of Dr.Fixit, Raincoat without dilution spreading @ the rate of 0.70/L/Sq.m/Coat. Allow to dry 1st coat for 24 hrs. Apply 2nd coat of Dr.Fixit, Raincoat without dilution Spreading at the rate of o.70/L/Sq.m/Coat to achieve total dry film thickness of 850/1000 microns at forced the coverage at the rate of 1.40/L/Sq.m in 2 coats. Ensure there are no air bubble and pin holes on the coating.
  • In comparison to other waterproofing our cost is cheaper.
  • We will give you written guarantee for three to five years(After the Guarantee Period the Chemical is Effective for 10-12 Years).

Why Do You Need Terrace Water proofing Services?
Waterproofing is one of the most critical, yet neglected subjects because the common man is not exposed to the concrete technology. He just wonders and is shocked when he sees leakage in his building, but most of the time he considers it as inconvenience rather than a serious matter.

1) Surface preparation cleaning, grouing etc.

2) Chemical coating by brush. (Sunanda-WP / Dr.Fixit-URP Mixing Ratio: 1:1 = 1kg Cement + 1 ltr Chemical)

4) Parapet wall and terrace slab junction watta: cement sand mortar 1:4 with wp compound.

5) Water ponding test 3 days.

6) Laying C.S. mortar layer (1:4) 25mm thick and laying brick bat coba (average 5” thickness) 1:100 slope.

7) Water ponding test 5 to 7 days.

8) Laying IPS (1:3 cement sand mortar)

9) Water ponding test 5 to 7 days.

10)Laying china mosaic chip’s